Partner login
GSM remote control RELLAY 5 (1DIn or 1temp,2tepl,1DOut, 230V
  • directly controlled socket 230V
  • controlled via SMS messages
  • automatic temperature regulation via temperature sensor

Extension – 2x temperature inputs for temperature sensors

Order No.: GSM-R5-ZAS-2A
Retail price Price on request
Wholesale price Price on request
Inquire
  • Select accessories
  • Product description
  • Technical specification
  • Commercial packaging
  • Accessories
  • Support

The GSM rele5 (GSM-R5-ZAS) device is actually an electrical outlet controlled by a mobile phone via SMS. This allows you to switch on and off the conventional electrical appliance 230 V / 50 Hz, 10 A, typically an oil radiator. To put the GSM rele5 into operation, just insert the SIM card of any operator. The GSM rele5 is also suitable for RESETing servers, routers or modems.

In practice, communication takes place by sending an SMS message in the form “1234 ZAP” (“1234 VYP”, etc.), where “1234” is your pre-set password, which of course you can change. The GSM relay 5 tells you that the instruction has been received. If you do not want this answer, send a message in the form “1234 ZAP ZAP”, meaning “DO NOT send a confirmation message”.

The GSM relay 5 is equipped with an analog input for temperature measurement. The current sensor temperature information is a part of the status message the GSM rele5 sends each time the SMS command is acknowledged or the “1234 STAV” command is requested. The GSM relay 5 can also regulate room temperature to the desired temperature by switching on and off the connected electrical appliance (such as an oil radiator). Just send an SMS message in the form “1234 TEPL 21” and the GSM rele5 will start to adjust to 21 ° C.

The GSM relay 5 can also be configured to send an SMS message when it drops or exceeds pre-set temperature limit. The report is sent to the phone number stored in the configuration under the name “MASTER”. The MASTER number is the number which the GSM relay 5 received first message from(e.g.: “1234 ZAP”)

GSM relay allows measuring the power and total consumption of the connected appliance. Based on the measured values, it is possible to send, for example, information messages about exceeding the specified power of the appliance or ofter reaching a certain total consumption.

GSM relay is equipped with button. It’s used for changing the state of the outlet (ON/OFF).

note: The temperature sensor is not included. You need to orded it separately. Recommended type is: GSM-C-T2

Expansion – 2 analog inputs for temperature measurement

Usage examples

  • holiday houses – remote controll of heating , water heating, air conditioning

  • Event announcement – door opening, windows, signal from security device
  • Room temperature control – Automatic switching on and off of the connected radiator
  • Monitoring the temperature drop below a set limit – the temperature is monitored at the connected temperature sensor
  • remote reset of computers
  • Switch on / off heating, el. Boiler, boiler, gas boiler, air conditioning, storage stoves – you can turn the heating on or off simply by sending an SMS message
  • Heating regulation according to non-frost temperature – connect the temperature sensor and set the required temperature via SMS. If the temperature drops below the set, you will automatically receive a warning SMS
  • Measuring the power voltage and total consumption

Advantages

  • Easy installation – simply by plugging into a mains socket without interfering with mains wiring
  • Simple controll – just send an SMS from your mobile phone.
  • Plug&Play – the basic setting is directly from the factory, no complicated setup is required
  • Reconfiguration – simple editing of phone numbers and other parameters from the SeaConfigurator
  • Datalogger for traffic data (e.g. temperature)

Setup and monitoring (configuration and monitoring sw)

The program SeaConfigurator is used for configuration. This software for PC provides connection either using USB cable or remotely using GPRS. The software is free to download and without any restrictions.

Controlling from your phone

  • SMS messages – the list of messages is available in User Manual
  • Application for Android and iOS

For the functionality of the CML application, it is necessary to have an activated data tariff on the SIM card, which is inserted in the device. Transferred data can be charged by the operator according to the tariff agreed by you.

 

To simplify and conveniently manage your devices from a range of GSM applications, we have developed an application for Android smartphones and iOS (Apple). This application is free of charge.

This app only serves to simplify control. It is not a condition for control. If you do not have an Android phone, you can control the device via SMS or ringing.

You can download this application from  Google Play or Apple Store for free, type into search „CML SEA“. After installing the application, make the first registration, take a photo of the QR code of the device into the “paring code”. The QR code you find in the GSM-R5-ZAS-2A package.

https://play.google.com/store/apps/details?id=cz.seapraha.cml

https://apps.apple.com/app/id1511530045

On-line Data on a website

You can monitor the measured values, including the history, and display them clearly on the cml.seapraha.cz website. You can also control the outputs or set up e-mails with alarm messages directly from the website.

Versions

Order number

Antenna connector

Internal battery

Basic temperature input

Expansion inputs and outputs

GSM-R5-ZASNONOYESNO
GSM-R5-ZAS-2AYESYESYES2x temperature
GSM-R5-ZAS-2INYESYESYES2x DIn *1)
GSM-R5-ZAS-3OUTYESYESYES3x DOut *1)
GSM-R5-ZAS-5INBYESYESYES5x DIn *2)

*1) Inputs and outputs are galvanically isolated from the device and between each other.

*2) Inputs and outputs are galvanically isolated from the device but have one common terminal.

Power supply:230 Vac (+/- 10%)
Outlet socket:230 Vac / 10 A maximum – resistive load *)
Device consumption:3 W; standby 1 W
Digital output:3x temperature, range -30°C to +55°C
Operating temperature:-20 aş +40 °C
Humidity:RHmax 90%
*)For loads greater than 10A or inductive or capacitive loads, use a different type of device
e.g.: GSM-R4-DIN with additional relay or contactor.

 

Variants

Ordering code

Antenna
connector

Internal
battery

Basic temp.
input

Extension for I/O

Price

GSM-R5-ZASNONOYESNOcall and ask
GSM-R5-ZAS-2AYESYESYES2x Temperaturecall and ask
GSM-R5-ZAS-2INYESYESYES2x DIn *1)call and ask
GSM-R5-ZAS-5INBYESYESYES5x DIn *2)call and ask

*1) Inputs and outputs are galvanically separated from the unit and from each other too.

*2) Inputs and outputs are galvanically separated from the unit,  but have one common terminal.

GSM-R5-ZAS -2A

A1, A5, A6
 3x temperature input fot temperature sensors  GSM-C-T2, GSM-C-T2.5 a GSM-C-T2.10

LED at the respective output indicates the status when the temperature sensor is connected.

 

1GSM relay
12 pin connector pitch 3,81mm
16 pin connector pitch 3,81mm (only with GSM-R5-ZAS-xxx version)
1antenna GSM-ANT11K (only with GSM-R5-ZAS-xxx)
1screwdriver 2mm
User manual CZGSM-R5-ZAS_User_Manual EN v2-09
USB drivery pro Windows (in Windows 10 driver is installed automatically) GSM-R5-ZAS_bgs5-drivers
SeaControl (program for controlling and monitoring GSM equipment from SEA)  GSM-CONTROL
SeaConfigurator (program for setting up and monitoring GSM devices SEA s.r.o.) GSM-CONFIGURATOR